Service - battery cell prototyping & testing

‍
Solid Energies Inc. (SEI) helps battery developers and product teams turn material concepts into testable cells and functional battery packs. Our services connect materials engineering, prototype fabrication, testing, and manufacturing development so you can evaluate performance, resolve design challenges, and prepare for scale-up.

Battery Cell/Pack Prototyping
Compare materials and cell designs in formats suited to the stage of development. Coin cells support early screening; custom pouch cells support multi-Ah (up to 50Ah) development and application-focused evaluation.
‍
Service                                                              Scope
Electrode Preparation                                Slurry preparation, (slot-die/doctor blade) coating, drying, calendering, die cutting
Electrolyte Integration                               Liquid, gel, semi-solid, all-solid-state systems, subject to material compatibility
Cell Assembly                                                Stacking, tab welding, electrolyte filling, sealing, formation, and degassing
Moisture Management                              Dry-room processing, with dew-point requirements defined for the chemistry
Pack integration                                            Cell packing, thermal management/modeling, BMS, packaging
Battery Cell Testing and Validation
Build a test plan around the decisions your team needs to make, from material selection and cell benchmarking to pack design verification.
‍
Service                                                              Purpose
Cycle life and calendar aging                  Track capacity, energy, resistance, and degradation under defined conditions.
DCIR and HPPC                                             Evaluate resistance and pulse-power behavior across operation conditions
Rate and temperature mapping            Characterize performance across selected charge, discharge, and temperature                                                                                 conditions (-70 deg C to +120 deg C) 
Electrochemical impedance
spectroscopy                                                 Investiagte resistance and interfacial changes in materials/cells.
Safety and abuse evaluation                  Nail penetration, overcharge, external short circuit, thermal-storage tests with                                                                                suitable sample and facilities

Cell testing up to 400A on 5V channels is subject to configuration, duty cycle, and sample requirements. Pack testing is scoped separately; temperature conditions must match the sample and equipment limits. Agree to test methods and acceptance criteria before testing. Product certification is a separate scope.


Accelerate Your Energy Storage Innovations
Expert Team | State-of-the-Art Lab | Tailored Solutions
Contact our Engineering Team to discuss your project specifications
Email: contact@solidenergies.com